Application
Dimension
Internal graph
Working principle
The working principle of the contactor: Upon energization, the circuit with current will create a magnetic field and generate sufficient magnetic adhesion to overcome counterforce, close armature and connect the contacts. When the coil voltage dies out or reduces to a certain value(i.e. at the state of voltage release), for the flux generated at the end face of the armature decreases, the magnetic adhesion becomes weaker than the counterforce generated by the reaction spring, contact spring, etc. Under the counterforce, the armature will be released and free from th efield yoke, and then the contacts will be disconnected.
Consumption
Attention
1. Confirm whether the product voltage, current, frequency and use category meet the requirements befor use;
2. Connect the control circuit first for no-load operation test and then connect the load in case of no abnormality;
3. Regularly tighten the terminals and remove the deposited dust;
4. Don't make the foreign matters fall into the product
.
Why choose us
AC contactor belongs to modular controlling electrical equipments,which has novelty structure,compact size ,it is DIN-RAIL for installation,size of modular,modeling artistic.use of safey,direct acting inversion.And,it can installde in the distribution boards along with breakers.
Technical data
Power circuit | ||
Voltage Rating(Ue) 1P, 2P |
250VAC |
|
3P, 4P |
400VAC |
|
Endurance(O-C) | ||
Electrical |
100000 cycles |
|
Maximum number of switching operation a day |
100 |
|
Additional characteristics | ||
Insulation voltage(Ui) |
500VAC |
|
Pollution degree |
2 |
|
Rated impulse withstand voltage(Uimp) |
2.5kV(4 kV for 12/24/48V AC) |
|
Degree of protection (IEC 60529) |
Device only |
IP20 |
Device in modular enclosure |
IP40 |
|
Tropicalization (IEC 60068-1) |
Treatment 2(relative humidity 95% at 55ºC) |
Dimension
Internal graph
Working principle
The working principle of the contactor: Upon energization, the circuit with current will create a magnetic field and generate sufficient magnetic adhesion to overcome counterforce, close armature and connect the contacts. When the coil voltage dies out or reduces to a certain value(i.e. at the state of voltage release), for the flux generated at the end face of the armature decreases, the magnetic adhesion becomes weaker than the counterforce generated by the reaction spring, contact spring, etc. Under the counterforce, the armature will be released and free from th efield yoke, and then the contacts will be disconnected.
Consumption
WCT contactors-50Hz | |||||
Raring(In) | Control voltage(V AC)(50Hz) | Consumption | Max. power |
||
AC7a | Holding | Inrush | |||
2P | 40A | 220...240 | 4.6 VA | 34 VA | 1.6 W |
Attention
1. Confirm whether the product voltage, current, frequency and use category meet the requirements befor use;
2. Connect the control circuit first for no-load operation test and then connect the load in case of no abnormality;
3. Regularly tighten the terminals and remove the deposited dust;
4. Don't make the foreign matters fall into the product
.
Why choose us